VRLA sealed lead acid
The default. Lowest capital cost, widely available, well understood. Shorter design life and materially affected by ambient temperature — every few degrees above 20 °C shortens it, which matters a great deal in the Kingdom.
Uninterruptible power supplies and battery systems for hospitals, data centres, airports, government facilities and commercial buildings — supplied in partnership with Amoori Trading, authorised reseller for Riello UPS and Schneider Electric (APC) in Saudi Arabia.
Most UPS disappointment comes from buying the wrong topology rather than the wrong brand or the wrong size. IEC 62040-3 classifies them, so a specification can be written precisely.
Mains is rectified to DC and re-inverted to AC continuously, so the load never sees the incoming supply. Zero transfer time and full conditioning. Required for anything where a few milliseconds matter — medical, data centre, process control.
Runs the load on filtered mains and corrects voltage through an autotransformer, switching to battery only on failure. Efficient and cost-effective for offices, comms rooms and edge equipment tolerant of a short transfer.
Passes mains straight through and switches to inverter on failure. The cheapest protection and appropriate for individual workstations — but not for anything a building depends on.
Workstations, comms cabinets, small server rooms and equipment racks.
| Range | Rating | Format |
|---|---|---|
| iPlug | 600 – 800 VA | Plug-in desktop |
| iDialog | 400 – 1600 VA | Tower |
| iDialog Rack | 600 – 1200 VA | Rack mount |
| Net Power | 600 – 2000 VA | Tower |
| Vision | 800 – 2000 VA | Tower |
| Vision Rack | 800 – 1100 VA | Rack mount |
| Vision Dual | 1.1 – 3 kVA | Tower / rack convertible |
| Sentinel Pro | 700 – 3000 VA | Tower, online |
| Sentinel Rack | 1.5 – 3 kVA | Rack mount, online |
| Sentinel Tower | 1.5 – 3 kVA | Tower, online |
Where the UPS starts serving a distribution board rather than a rack.
| Range | Rating | Notes |
|---|---|---|
| Sentinel Dual (low power) | 1000 – 3000 VA | Single and three-phase input options |
| Sentinel Dual SDU | 4 – 10 kVA | Online double conversion |
| Sentryum | 10 – 120 kVA | Compact three-phase |
| Sentryum Rack | 20 – 160 kVA | Rack integrated |
| Master MPS | 10 – 200 kVA | Three-phase |
| Master Industrial | 30 – 80 kVA | Industrial duty |
| Master FC400 | 30 – 125 kVA | Three-phase |
Modular and scalable frames where capacity is added in increments and redundancy is designed in from the start.
| Range | Rating | Notes |
|---|---|---|
| Multi Sentry | 160 – 200 kVA | Transformer-based three-phase |
| Multi Power | 45 – 294 kVA | Modular |
| Multi Power 2 | 300 – 600 kVA | Modular |
| Multi Power 2 Scalable | 1000 – 1600 kVA | Scalable modular frame |
| NextEnergy NXE | 250 – 800 kVA | High efficiency |
| Master HP | 100 – 600 kVA | High power |
| Master HE | 100 – 800 kVA | High efficiency |
| Master HP UL | 65 – 500 kVA | UL listed variant |
The battery decides the running cost, the footprint and how often someone has to come back. It is worth more attention than it usually gets.
The default. Lowest capital cost, widely available, well understood. Shorter design life and materially affected by ambient temperature — every few degrees above 20 °C shortens it, which matters a great deal in the Kingdom.
Higher capital cost, considerably longer service life, far smaller and lighter for the same autonomy, and much more tolerant of heat. Often the cheaper option measured across the life of the installation rather than the purchase order.
Very high cycle life and near-instant recharge, with short autonomy by design. Suited to ride-through duty where a generator picks up within seconds and the UPS only has to bridge the gap.
Runtime is specified from the load profile and what happens next — orderly shutdown, generator start, or full ride-through. Parallel and N+1 configurations where a single frame failure must not take the load with it.
Crossworld Trading supplies these systems in partnership with Amoori Trading LLC, who hold the authorised reseller appointment in Saudi Arabia for Riello UPS and Schneider Electric (APC). The manufacturer authorisation, warranty and factory-backed service sit with Amoori. Specification, pricing, import, clearance and delivery sit with us.
We are explicit about that split because a UPS is not a one-off purchase. It needs commissioning, battery replacement on a schedule, and someone contactable when it alarms at two in the morning. Knowing which company does which part before you buy is worth more than a slightly better price.