The cable that carries signals, not load.

Structured cabling, fibre backbone, building controls and instrumentation. Lower voltage, higher consequence — a power cable that underperforms trips a breaker, whereas a data cable that underperforms produces intermittent faults nobody can find.

Categories

What we supply.

Four families, all available in low smoke zero halogen construction and in riser or plenum grades where the design calls for them.

01

Structured Cabling

Cat 6, Cat 6A and Cat 7 horizontal and backbone copper, in U/UTP, F/UTP and S/FTP constructions. For commercial buildings, campuses and mission-critical installations where the cabling has to certify to a channel test, not just pass a continuity check.

ISO/IEC 11801 · TIA-568 · EN 50173
02

Fibre Optic

Single-mode OS2 and multimode OM3, OM4 and OM5. Loose tube and tight buffered, indoor, outdoor and indoor/outdoor rated, armoured where rodents or mechanical risk demand it. Campus backbone, riser, office trunking and FTTx distribution.

ITU-T G.652.D · IEC 60793 · IEC 60794
03

Building & Control Cable

BMS and BAS field wiring, ventilation and damper control, valve actuators, access control and door hardware. Screened and unscreened, in the core counts and conductor sizes the controller manufacturer actually specifies.

BMS · BAS · access control
04

Instrumentation Cable

Individually screened pairs, collectively screened pairs, or both, for 4–20 mA loops and field instrumentation. The screening arrangement is the specification — getting it wrong shows up as drift and noise long after commissioning.

BS 5308 Part 1 & Part 2 · IS/OS pairs
05

KNX Bus Cable

Certified bus cable for KNX building automation — lighting scenes, blinds, HVAC zoning and room control. Twisted pair with the correct impedance and colour convention, so commissioning tools behave the way the documentation says.

KNX certified · twisted pair · bus
06

Telecommunication Cable

Voice, data and signal transmission cable for internal distribution and riser duty, including multipair backbone for legacy voice and paging systems still in service across large estates.

Voice · multipair · riser
Reference

Categories and grades at a glance.

The numbers that decide whether an installation will certify.

Copper structured cabling
CategoryBandwidthTypically supports
Cat 6250 MHz1 Gb/s to 100 m; 10 Gb/s over reduced length
Cat 6A500 MHz10 Gb/s to 100 m — the usual choice for new build
Cat 7600 MHz10 Gb/s with individually screened pairs
Optical fibre
GradeTypeTypical use
OS2Single-mode, 9/125 µmCampus and inter-building backbone, FTTx, long runs
OM3Multimode, 50/125 µm laser optimised10 Gb/s to 300 m in data centres and risers
OM4Multimode, 50/125 µm10 Gb/s to 550 m; higher rates over shorter spans
OM5Wideband multimodeShort-wavelength division multiplexing
ISO/IEC 11801TIA-568EN 50173IEC 61156 ITU-T G.652.DIEC 60793IEC 60794BS 5308IEC 60332
Where it comes from

Named manufacturers, named on the quotation.

Low current cable is the category where substitution does the most damage, because the difference between a certified Cat 6A channel and a cable that merely says Cat 6A on the drum only appears when the installation is tested — by which time it is in the ceiling.

Through our partnership with Amoori Trading LLC we supply internationally certified cable from established manufacturers, named against each line so your consultant can check the datasheet before you order rather than after.

If a specification names a manufacturer we cannot source, we will say so rather than quote an equivalent and let the difference surface at handover.

Manufacturers supplied

Available through the Amoori Trading partnership:

BeldenCommScopePrysmian DatwylerMESCB3 International

Manufacturer names are shown to identify the products supplied. All trademarks belong to their respective owners. Crossworld Trading is not an authorised agent or distributor for these manufacturers.

Ask about a specification
Data & control

Send the containment schedule and the channel spec.